Valve Position Bright/Dim Illumination Control
| Normal Operation: | |||||
| Some indicators require three states of illumination to show positional information. The three states are OFF, DIM and BRIGHT. The indicator voltages for each state: | |||||
| BRIGHT = 28v DC | |||||
| DIM = 16v DC | |||||
| OFF = 0 v DC | |||||
| The indicators that provide three states of illumination are not wired to S3 "MASTER BRIGHT/DIM/TEST LIGHTS SWITCH" control (Instrument Panel P1-2) for setting indicator brightness. Indicator brightness is ONLY controlled by the valve position that the indicator is monitoring. They are wired to S3 "MASTER BRIGHT/DIM/TEST LIGHTS SWITCH" for the "TEST" function. | |||||
| The crossfeed valve open light is an example of a indicator using three states of illumination. | |||||
| Example: | |||||
| FUNCTIONAL DESCRIPTION - FUEL CROSSFEED VALVE | |||||
| General | |||||
| The fuel crossfeed valve switch controls the crossfeed valve. When you move the switch to the open or closed position, 28v dc power goes through a switch assembly to the actuator. The actuator then moves the crossfeed valve to the applicable position. | |||||
| The printed circuit card assembly controls the operation of the crossfeed valve open light. The printed circuit assembly receives fuel crossfeed valve position and fuel crossfeed valve switch position information. | |||||
| When the fuel crossfeed valve is closed, the crossfeed valve open light is off (zero volts). When the fuel crossfeed valve position and fuel crossfeed valve switch position disagree, the crossfeed valve open light is on bright (twenty eight volts). When the fuel crossfeed valve is open, the crossfeed valve open light is on dim (sixteen volts). | |||||
| Indicator Locations: | |||||
| LOC | Module # | ID # | Legend | Illumination | Description |
| FUEL | P5-2 | L10 | ENG VALVE CLOSED | OFF 0 vdc | ENGINE 1 FUEL VALVE IS OPEN |
| DIM 16vdc | ENGINE 1 FUEL VALVE IS CLOSED | ||||
| BRIGHT 24vdc | ENGINE 1 FUEL VALVE IS IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| FUEL | P5-2 | L1 | SPAR VALVE CLOSED | OFF 0 vdc | ENGINE 1 SPAR FUEL VALVE IS OPEN |
| DIM 16vdc | ENGINE 1 SPAR FUEL VALVE IS CLOSED | ||||
| BRIGHT 24vdc | ENGINE 1 SPAR FUEL VALVE IS IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| FUEL | P5-2 | L11 | ENG VALVE CLOSED | OFF 0 vdc | ENGINE 2 FUEL VALVE IS OPEN |
| DIM 16vdc | ENGINE 2 FUEL VALVE IS CLOSED | ||||
| BRIGHT 24vdc | ENGINE 2 FUEL VALVE IS IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| FUEL | P5-2 | L2 | SPAR VALVE CLOSED | OFF 0 vdc | ENGINE 2 SPAR FUEL VALVE IS OPEN |
| DIM 16vdc | ENGINE 2 SPAR FUEL VALVE IS CLOSED | ||||
| BRIGHT 24vdc | ENGINE 2 SPAR FUEL VALVE IS IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| FUEL | P5-2 | L3 | VALVE OPEN | OFF 0 vdc | CROSSFEED VALVE IS CLOSED |
| DIM 16vdc | CROSSFEED VALVE IS OPEN | ||||
| BRIGHT 24vdc | CROSSFEED VALVE IS IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| ICE | P5-11 | L6 | L VALVE OPEN | OFF 0 vdc | LEFT WING VALVE IS CLOSED |
| DIM 16vdc | LEFT WING VALVE IS OPEN | ||||
| BRIGHT 24vdc | LEFT WING VALVE IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| ICE | P5-11 | L4 | R VALVE OPEN | OFF 0 vdc | RIGHT WING VALVE IS CLOSED |
| DIM 16vdc | RIGHT WING VALVE IS OPEN | ||||
| BRIGHT 24vdc | RIGHT WING VALVE IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| ICE | P5-11 | L1 | COWL VALVE OPEN | OFF 0 vdc | ENGINE 1 COWL VALVE CLOSED |
| DIM 16vdc | ENGINE 1 COWL VALVE OPEN | ||||
| BRIGHT 24vdc | ENGINE 1 COWL VALVE IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| ICE | P5-11 | L2 | COWL VALVE OPEN | OFF 0 vdc | ENGINE 2 COWL VALVE CLOSED |
| DIM 16vdc | ENGINE 2 COWL VALVE OPEN | ||||
| BRIGHT 24vdc | ENGINE 2 COWL VALVE IN TRANSIT | ||||
| OR VALVE AND SWITCH DISAGREE | |||||
| Simulator Solution: | |||||
| A 12V Zener diode could be used to provide the reduction in Brightness for the Dim mode. This 12v zener diode could be wired to terminal number two (2) of a Korry 318 Chromalux® indicator "Circuit type 1" in series with a single pole switch to ground. A second switch could be wired in parallel with the 12v zener diode, and when it is closed the Bright mode (28V) would result. | |||||
![]() |
| Logic Table for Korry Indicator legend "VALVE CLOSED" | |||
| VALVE POSITION | 12V Zener Switch 1 (S1) | Switch 2 (S2) | ILLUMINATION |
| OPEN | OPEN | OPEN | OFF |
| TRANSIT | OPEN OR CLOSED See Note 1 | CLOSED | BRIGHT |
| CLOSED | CLOSED | OPEN | DIM |
| Note 1: For more realistic operation close S1 and S2 for BRIGHT, then open S2 for DIM, or both S1, S2 for OFF | |||
| Logic Table for Korry Indicator legend "VALVE OPEN" | |||
| VALVE POSITION | 12V Zener Switch 1 | Switch 2 | ILLUMINATION |
| CLOSED | OPEN | OPEN | OFF |
| TRANSIT | OPEN OR CLOSED See Note 1 | CLOSED | BRIGHT |
| OPEN | CLOSED | OPEN | DIM |
| Note 1: For more realistic operation close S1 and S2 for BRIGHT, then open S2 for DIM, or both S1, S2 for OFF | |||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |